I
|
Home IMPEDANCE TESTER / INFRARED
OPTICAL THERMOMETER / HUMIDITY & NON CONTACT
INSULATION
TESTER - ANALOG & DIGITAL
/ HAND DRIVEN TYPE / INSULATION
TESTER CHECKER / INTELLIGENT METER
|
1506-IM AUDIO IMPEDANCE TESTERBattery powered
Audio Impedance Tester. Timer function for hand free use. Battery idicator.
The tester measure with a frequency of 1KHz. Measure speakers impedance. Measure
speaker lines (connected to load). Help to check audio power systems. Ideal
for publicaddress installation and maintanance. Can measure transformer
impedance. Specification :
Measurement system : Constant current inverter inverter with 1KHz approx.
2mA. Measuring Ranges : 20 / 200 /2KW. Accuracy : Within +2.5% of
full scale. Power Source : 1.5V x
6pcs Dry battery. |
|
|
9811 PRINTING / DATALOGGING IR THERMOMETER.
Measuring range : -40oC~ 500oC ( -40oF ~932oF). Accuracy : +/-2% or 2oC whichever is greater, under
-20oC : +/-3% or 3oC whichever is greater. Emissivity adjustable from 0.3 ~
1.0. Resolution : 0.1oC / 0.1oF (<100oC) others 1oC / 1oF. Distance ratio : 8 : 1. Response time :
0.2 seconds. Auto Power Off
for saving battery life. Printer : 38mm
Thermo-printer, 38 x 30mm
thermo-paper. Meter size :
Approx. 208(H) x 70(W) x 53(T)mm Matrix LCD.
Weight : 260 grams. RS-232C Software
enable to connect with PC. Backlight, Laser sighting selectable. |
|
|
Model |
8861 |
8868 |
8866 |
8886 |
||
|
|
|
|
|
|
||
|
Temp. Range |
-20~420oC (-4
to 788oF) |
|||||
|
Accuracy |
+ 2.5% of reading |
+ 2% of
reading |
||||
Distance / Spot Ratio
|
8 : 1 |
10 : 1 |
8 : 1 |
|||
|
Max / Min / DT / Avg. Temp. |
Yes |
No |
Yes |
|||
|
Emissivity Settings |
0.95 Fixed |
Adjustable 0.3~1.0 |
3 Point
Selectable (0.85 / 0.90 / 0.95) |
|||
|
9 Point Memory |
Yes |
No |
Yes |
|||
|
Laser Sighting |
No |
Yes |
||||
|
Model |
DT - 8811 |
DT - 8812 |
DT - 8819H |
DT - 8829 |
|
CEM |
|
|
|
|
|
Range |
-20o~450oC (-4o~842oF) |
-50o~500oC (-58o~932oF) |
-50o~750oC (-58o~1382oF) |
-50o~1000oC (-58o~1832oF) |
|
Response Time |
Less
than 1 second |
|||
|
Resolution |
1oC / 1oF |
0.1o up to 200o (1o over 200o) |
||
|
Basic Accuracy |
+2% of reading or +2oC/+4oF |
+1.5% of
reading or +2oC / +4oF (whichever
is greater) |
||
|
Distance : Spot |
8 : 1 |
16 : 1 |
50 : 1 |
|
|
Emissivity |
Fixed
at 0.95 |
Adjustable
0.1~1.0 |
Fixed
at 0.95 |
|
|
Model |
TPI - 376 2 IN 1 Infra |
TPI 377 2 IN 1 Infra |
TPI - 384 |
|
|
|
|
|
||
Temperature Range
|
-50o ~ 510oC (-58o ~ 950oF) |
-18o ~ 1000oC (-58o ~ 1832oF) |
-20o ~ 1000oC (-4o ~ 1832oF) |
|
|
Accuracy +23oC x=0.95 |
+2% of
reading or +3.5oF (2oC) whichever is greater |
|||
|
Response Time |
500
milliseconds |
|||
|
Spectral Response |
7 ~
14um |
8 ~
14um |
||
|
Distance : Spot |
8 : 1 |
|||
|
Emissivity |
0.3 ~
0.99 adjustable |
0.95 |
||
|
Display Resolution |
0.1oF and 0.1oC or 1oF and 1oC |
|||
|
Ambient Operating Range |
32o ~ 120oF and 0o ~ 50oC |
|||
K type Probe
|
Range |
-40o ~ 2192oF and
-40o ~ 1200oC |
|
|
|
ST-150 (Optional) |
Accuracy |
+(0.5%
of reading +3oF)] |
|
|
|
Laser Sighting with Display Data Hold Function. |
||||
|
IR-68 FLEXIBLE
GOOSENECK INFRARED THERMOMETER WITH LASER TARGETING
16 inch Gooseneck
detector is easy to measure the hard to reach areas. White Backlight
illuminates display for measurements at night or in areas with low background light levels. Overrange
Indication. Auto Data Hold when
measure released. Auto Power Off. Specification : Range
-50oC ~ 600oC (-58oF ~ 1112oF). Response Time < 1 second. Resolution 0.1o up to 200, 1o over 200o. Basic Accuracy +2% of reading or +2oC / +4oF. Emissivity Fixed at 0.95. Distance : Spot - 8 : 1. Power Supply : 9V Alkaline Battery. |
|
|
TN305LC 2 IN 1 INFRARED THERMOMETER with K
Type (K Types Probe is Optional). Range : -60~500oC
(-76~932oF). Operating Range : 0~50oC (32~122oF). Accuracy : +2%,
2oC whichever is greater. Resolution
(-9.9~199.9oC) : 0.1oC / 0.1oF. Distance to Spot
Ratio 8 : 1. Emisivity : 0.1~1 Adjustable. Measurement Range
of Probe : -64~1400oC (-83.2~1999oF). Accuracy : +1%,
1oC whichever is greater. Mode : Ave, Dif
HiLow Alarm, Max, Min, Lock. Backlite, Buzzer. Power Supply : LR6
/ AA x 2. |
|
|
TCT103 2 IN 1 INFRARED THERMOMETER with K
Type Range : -33~220°C
(-27~428°F). Operating Range : 0~50°C (32~122°F). Accuracy : +2%,
2oC whichever is greater. Resolution (-9.9~199.9oC) :
0.1oC / 0.1oF. Distance : Spot
Ratio 1 : 1. Emisivity : 0.1~1 Adjustable. Measurement Range
of Probe : -55~330°C. Accuracy : +0.8°C,1%
whichever is greater. Mode : Max, Min, Lock.
Power Supply : CR2032 x 1. |
|
368 Pocket Size digital Non-Contact Thermometer Range -22o~120oC
(-7o~240oF). Operating Temperaute 0o~40oC (32o~104oF). Accuracy +2% or reading or +2oC,
whichever is greater. Response Time Less than 0.5sec. Resolution
0.1oF/C. Emissivity 0.95 fixed. Distance : Spot Ratio - 1 : 1.3.
Battery A003. |
|
|
TM 910 NARROW SPOT INFRARED THERMOMETER
Useful Instrument to measure the
surface Temperature of small size and narrow spot target, such as IC, Transistor,
Coil, Transformer. LCD 0.5 Display. Temperature Ranges : -10oC~300oC,
14oF~572oF. Accuracy : +2% of reading or 2oC
(3oF), which ever is greater. Emissivity : 0.10~0.95. Operating
Temperature : 0oC~50oC (32oF~122oF). Data Output : RS-232 serial PC
interface (Cable Optional). Operating Humidity : < 80% RH.
Sampling Time : Approx. 1sec Power supply : DC 9V Battery.
Distance to Spot Ratio - 10 : 1. |
|
|
TM-2000 3 in 1 INFRARED THERMOMETER + Pt 100W
+ Type K/J/R/E/T with Emissivity. Distance to Spot Ratio - 8 : 1
|
|
||
|
TYPE |
RESOLUTION |
RANGE |
|
Infrared Thermometer
|
1oc |
-20oC
~ 400oC |
|
|
PT 100 |
0.1oC |
-200.0oC
~ 850.0oC |
|
|
Thermocouple K |
0.1oC |
-100.0oC
~ 1300.0oC |
|
|
Thermocouple J |
0.1oC |
-100.0oC
~ 1150.0oC |
|
|
Thermocouple T |
0.1oC |
-100.0oC
~ 400.0oC |
|
|
Thermocouple E |
0.1oC |
-100.0oC
~ 900.0oC |
|
|
Thermocouple R |
1oC |
0oC
~ 1700.0oC |
|
|
GRILLO-H ITALY make HIGH TEMPERATURE
INFRA RED THERMOMETER with Emissivity Setting Range : 600~1400oC /
700~1600oC /1000~1800oC with LASER. Working Wavelength : 1mm. Focusing Distance : from 800mm to infinite. Response Time : 5ms. emissivity Range
: Adjustable from 0.2 to 1.00. Target Diameter : 10mm a 800mm.
Pointing System : Red LASER class 3A. Accuracy : 1% +1oC. |
|
|
MT-4 MINI TEMP Non-Contact Thermometer
*Temperature Range : -18o~260oC.
*Accuracy : +2% of Reading. Preset Emissivity : 0.95. *Distance
to Spot Size : 6:1. *Dimension : 38mm (6 x 4 x 1.5in).
*Weight : 227g. |
|
|
OPTEX JAPAN X-400 THERMO-HUNTER Portable Non-Contact Thermometer for
surface Temparature Measurement Range : 0°C~400°C,
Back-light indicator, Measurement Area ψ100/1000mm. Backlight Function
enable. MAX Function to indicate the Maximum Temperature during your
Measurement with Emissivity Ratio. |
|
|
OPTEX JAPAN PT-2LD THERMO-HUNTER Measuring Range : -40~510oC
(-40~950oF). Distance to Spot Ratio : 10 : 1. Accuracy : For Less than 0oC : +3oC,
0~200oC : +2oC. Repeatability : +1oC
(2oF) of reading value. Emissivity : 0.95/0.7 (Switchable). Backlight. Temperature Unit : oC
/ oF. |
|
|
SMART SENSOR AR-882 INFRARED THERMOMETER. Range : -18 ~ 1500oC (0 ~ 2732oF). Distance to Spot Ratio : 50 : 1. Accuracy : 2oC or +2o%. Repeatability : +1oC (2oF) or 1% of reading value. Emissivity : 0.95 (Pre-set). Spectral Response : 8 ~ 14um. Ambient Operation Range : 0 ~ 40oC (32 ~ 104oF). Response Backlight. Temperature Unit : oC / oF. |
|
|
ITC 6 Insulation Tester
Checker.
Checking Ohm ranges
of Multimeters. Checking Low Ohm
range on Insulation Testers. Checking Insulation
Mega Ohm ranges on Insulation testers. Cheking Ohm ranges
on Clamp Meters. Checking range on
Milli-Ohm meters. Checking bench top
Multimeters Ohm Range. |
|
|
|
|
1832-IN. ANALOG INSULATION
TESTER
Battery Operated
and designed for very low power
consumption. Visual and Acoustic indication of Warning Voltage. Specification
: DC Test Voltage : 1000V, 500V, 250V. Measuring Range : 1000V, 0-400MW. Output Voltage : Open Circuit @ 1000V, +20% - 0%. Min. Rated
Voltage @ 1000V, 1mA. Output Short Circuit Current (Insulation) : + 1.3mA.
Accuracy Guaranteed Ranges : 0.05, 10MW 0 - 20MW / 0.2-40MW, +3%. Measuring Range Continuity : 0 - 3W. Measuring Range Resistance : 0 - 500W. Accuracy : 0-3W and 0-500W (%F.S.) : +1.5%. Open Circuit Voltage
Output : +5V. Short Circuit Current Output : >210mA. AC
Voltage Range : 0-600V. Accuracy : (% of full scale) : +2.5%. Input
Impedance : 1.2MW. |
|
|
MODEL |
3121 |
3122 |
3123 |
3124 |
||
|
|
|
|
||||
DC Test Voltage
|
2500V |
5000V |
5000V |
10000V |
1k~10kV
variable |
1000V |
|
Measuring Ranges (automatic change) |
2GW / 100GW (autoranging) |
5GW / 200GW (autoranging) |
5GW / 200GW (autoranging) |
10GW / 400GW (autoranging) |
1.6GW / 100GW (autoranging) |
100MW |
|
Primary Effective Measuring Ranges Accuracy |
0.1 ~
50GW |
0.2 ~ 100GW |
0.2 ~
100GW |
0.4 ~
200GW |
0.05 ~
50GW |
1 ~
100MW |
|
+5% rdg |
+10% rdg |
|||||
|
Other ranges Accuracy |
+10% rdg
or 0.5% of scale length |
+1% of
scale length |
||||
|
Output Voltage and Set Voltage Indicate |
--- |
DC 0 ~
10KV +2% |
||||
Withstand Voltage
|
5000V
AC for 1 minute |
|||||
Power Source
|
R6P
(AA) (1.5V) x 8 |
Ni-Cd rechargeable battery (1.2V) x 8 |
||||
|
Dimensions |
200 (L)
x 140(W) x 80(D) mm |
200 (L)
x 140(W) x 80(D) mm |
||||
|
Model |
UR 2060 |
UR-2061 |
UR 2070 |
UR 2071 |
UR 2072 |
|
|
Display Mode
|
Digital |
||||||
Rating Voltage
|
100/250/500/1000 |
500/1000/2000/2500 |
500V |
1000V |
500V /
1000V |
||
|
Terminal Voltage |
Rating
Voltage : +5% |
||||||
|
Rating Resistance (MW) |
0 ~
2000 |
||||||
|
Minimum Division |
1MW |
||||||
|
Accuracy |
1 ~
1000 MW +(5%reg + 3d) / 1001 ~ 1999MW : +(10%reg
+ 5d) |
||||||
|
Short Current (mA) |
> 1.5 |
||||||
V AC
|
--- |
|
|||||
Battery Check
|
Yes |
||||||
|
Insulation Resistance |
>50MW
(1000V) |
||||||
|
Operating
Temp. & Humidity |
0 ~ +40oC 85%RH |
||||||
|
Power Source |
6 x
1.5V battery type R6, AA SUM -3 |
||||||
|
Model |
3001B |
3111V |
||
|
Insulation
Resistance |
Continuity
Test |
Insulation
Resistance |
Continuity
Test |
|
|
Test
Voltage |
500V/1000V |
|
250V/500V/1000V |
|
|
Measuring
Range (Mid-scale
Value) |
200MW (2/20/200MW) auto
ranging |
200W(20/200W) auto
ranging |
0-100MW(1MW)/ 0-200MW(2MW)/ 0-400MW(4MW) |
50W(20W) |
|
Output Voltage on open
circuit |
Rated
Test Volt. +12% |
600mV
DC approx. |
Rated
Test Volt. +10% |
0.6V DC
approx. |
|
Rated Current |
1~1.2mA
DC approx. |
|
0.8mA DC approx. |
|
|
Output Short Circuit
Current |
1.5mA
DC approx |
6mA
approx. |
2mA DC approx. |
300mA
approx. |
|
Accuracy Guaranteed
Ranges |
|
|
0.05~10MW /
0.1~20MW/ |
|
|
Accuracy |
+2%rdg +5dgt |
+2%rdg +0.1W+1dgt |
+5% of
indicated value |
+3% of
scale length |
|
|
KEW-3007 Japan make. Digital Insulation Tester Measuring
Range DC Test Voltage 250V / 500V / 1000V. Resistance 0-20W / 0-200MW / 0-2000MW with live circuit
warning Buzzer.
0.7 LCD Battery operated Plastic
Body with Automatic Zero Aduj. Measuring Range 200mW / 500V, 1000mW / 1000V sampling time 0.4 second. |
|
|
|
|
|
||||||
SEW-2803 / 2804
|
SEW-6210 / 6211 |
SEW-6212IN |
||||||
Model
|
2803 - IN |
2804 - IN |
||||||
Test Voltage
(DC V) |
0.5KV |
1KV |
2.5KV |
5KV |
1KV |
2.5KV |
5KV |
10KV |
|
Measuring Ranges |
0-25GW |
0-50GW |
0-125GW |
0-250GW |
0-50GW |
0-125GW |
0-250GW |
0-500GW |
|
Accuracy |
0-50GW : +3%
of reading/50-250GW : +5% of reading |
0-50GW : +3%
of reading/50-500GW : +5% of reading |
||||||
|
Dimensions |
120 (L)
x 170(W) x 95(D) mm |
|||||||
|
Power Source |
1.5V
(AA) x 8 batteries |
|||||||
|
Features |
Microprocessor controlled
with advanced safety features. Displays external voltage
warning if present.
Auto-ranging / Auto-off. Real-time bargraph display
of test voltage and voltage decay during discharge. |
|||||||
Model
|
6210 - IN |
6211 - IN |
6212 - IN |
||||||
|
Test Voltage (DC V) |
0.5KV |
1KV |
2.5KV |
5KV |
1KV |
2.5KV |
5KV |
10KV |
0.5kV
to 10kV (0.5kV
increment steps) |
|
Measuring Ranges (Auto Ranges) |
0-25GW |
0-50GW |
0-125GW |
0-250GW |
0-50GW |
0-125GW |
0-250GW |
0-500GW |
25GW /
0.5kV 25GW at
0.5kV 500GW at
10kV |
|
Accuracy |
+ 3% rdg
+ 1 dgt |
||||||||
Output Current Limit
|
50uA to
100uA (1W) |
||||||||
|
Live Warning |
>
500V AC |
||||||||
|
Operating Temp. |
0o - 40o C |
||||||||
|
Humidity |
85% |
||||||||
|
Dimensions |
330(L)
x 260(W) x 160(D) mm |
||||||||
|
Power Source |
1.5V
C Alkaline x 8 batteries |
||||||||
|
Features |
Four
insulation test voltages (DC V) (6210-IN & 6211-IN) Insulation test Voltages
Bargraph indicates test voltage, decay can be observed during discharge.
(0.5kV - 10kV) (6212-IN)
Measure insulation test time.
Display warning of external voltage. |
||||||||
|
|
|
|
|
|
|
YK-2001TM |
YK-200PAM |
YK-200PLX |
YK-200PIR |
YK-200PRH |
|
YK-2001TM
INTELLIGENT Type K/J THERMOMETER
Dual function meters Super Large 3.½ Digit LCD Display. Master
meter is a professional Type K and Type J Thermometer. Microprocessor circuit assures maximum possible accuracy during the
measurement. Optional expandable plugs satisfy your different measurement
demands one time on wide velocity (Anemometer), light intensity (Light meter), None contact temperature (IR
thermometer), and relative humidity (Humidity meter). Provide you the most convenient way on measuring. 0.1 degree
resolutions for type K and type J thermometer. Record maximum and minimum readings. Data Hold, oC / oF. Measurement : Type K & J thermocouple. Range : Type K :
-100.0~1300.0oC. Type J : -100.0~1150.0oC. Data Output : RS232 PC Serial Interface. OPTIONAL TEMPERATURE PROBE & OTHER ACCESSORIES : YK-200PAM Metal Vane Anemometer Probe : 0.5~40.0m/sm 1.8~144.0km/h,
1.1~89.4mile/h, 1.0~78.1knots, 100~7880ft/min. YK-200PLX Light Meter Probe : Lux - 2,000 / 20,000 / 50,000 Lux. Feet Candle -
200 / 2,000 / 5,000 FC. YK-200PIR IR Thermometer Probe : Range -10~300oC / 14~572oF. IR Sensor - Thermocouple Pie. Emissivity Setting - 0.95.
Measurement Wave length Region - 6~12 micro meter. Distance Spot Ratio - 7:1. YK-200PRH Humidity Probe : Humidity Range - 10%~95%RH. Temperature Range - 0~50oC / 32~122oF. RS-232 : Cable for data transmission. SW-U801-WIN : Software for Data Logging. |