Nunes Instruments

I

Home IMPEDANCE TESTER / INFRARED – OPTICAL THERMOMETER / HUMIDITY & NON CONTACT

INSULATION TESTER - ANALOG & DIGITAL / HAND DRIVEN TYPE / INSULATION TESTER CHECKER / INTELLIGENT METER

 


IMPEDANCE TESTER


  1506-IM AUDIO IMPEDANCE TESTER

 

Battery powered Audio Impedance Tester. Timer function for hand free use. Battery idicator. The tester measure with a frequency of 1KHz. Measure speaker’s impedance. Measure speaker lines (connected to load). Help to check audio power systems. Ideal for publicaddress installation and maintanance. Can measure transformer impedance.

Specification : Measurement system : Constant current inverter inverter with 1KHz approx. 2mA. Measuring Ranges : 20 / 200 /2KW. Accuracy : Within +2.5% of full  scale. Power Source : 1.5V x 6pcs Dry battery.

 


INFRARED / OPTICAL THERMOMETER


  9811 PRINTING / DATALOGGING IR THERMOMETER.

• Measuring range : -40oC~ 500oC ( -40oF ~932oF).

• Accuracy : +/-2% or 2oC whichever is greater, under -20oC : +/-3% or 3oC whichever is greater.

• Emissivity adjustable from 0.3 ~ 1.0.

• Resolution : 0.1oC / 0.1oF (<100oC) others 1oC / 1oF.

• Distance ratio : 8 : 1.

• Response time : 0.2 seconds.

• Auto Power Off for saving battery life.

• Printer : 38mm Thermo-printer,  38 x 30mm thermo-paper.

• Meter size : Approx. 208(H) x 70(W) x 53(T)mm

• Matrix LCD. Weight : 260 grams.

• RS-232C Software enable to connect with PC. Backlight, Laser sighting selectable.

 


Model

8861

8868

8866

8886

Temp. Range

-20~420oC (-4 to 788oF)

Accuracy

+ 2.5% of reading

+ 2% of reading

Distance / Spot Ratio

8 : 1

10 : 1

8 : 1

Max / Min / DT /

Avg. Temp.

Yes

No

Yes

Emissivity Settings

0.95 Fixed

Adjustable 0.3~1.0

3 Point Selectable

(0.85 / 0.90 / 0.95)

9 Point Memory

Yes

No

Yes

Laser Sighting

No

Yes


Model

DT - 8811

DT - 8812

DT - 8819H

DT - 8829

CEM

Range   

-20o~450oC

(-4o~842oF)

-50o~500oC

(-58o~932oF)

-50o~750oC

(-58o~1382oF)

-50o~1000oC

(-58o~1832oF)

Response Time

Less than 1 second

Resolution

1oC / 1oF

0.1o up to 200o (1o over 200o)

Basic Accuracy

                +2% of reading or +2oC/+4oF

+1.5% of reading or +2oC / +4oF

(whichever is greater)

Distance : Spot

8 : 1

16 : 1

50 : 1

Emissivity

Fixed at 0.95

Adjustable 0.1~1.0

Fixed at 0.95


Model

TPI - 376 2 IN 1 Infra

TPI – 377 2 IN 1 Infra

TPI - 384

 

Temperature Range

-50o ~ 510oC (-58o ~ 950oF)

-18o ~ 1000oC (-58o ~ 1832oF)

-20o ~ 1000oC (-4o ~ 1832oF)

Accuracy +23oC x=0.95

+2% of reading or +3.5oF (2oC) whichever is greater

Response Time

500 milliseconds

Spectral Response

7 ~ 14um

8 ~ 14um

Distance : Spot

8 : 1

Emissivity

0.3 ~ 0.99 adjustable

0.95

Display Resolution

0.1oF and 0.1oC or 1oF and 1oC

Ambient Operating Range

32o ~ 120oF and 0o ~ 50oC

‘K’ type Probe

Range

-40o ~ 2192oF and -40o ~ 1200oC

 

ST-150 (Optional)

Accuracy

+(0.5% of reading +3oF)]

 

Laser Sighting with Display Data Hold Function.


 IR-68 FLEXIBLE GOOSENECK INFRARED THERMOMETER WITH LASER TARGETING

 

• 16” inch Gooseneck detector is easy to measure the hard to reach areas.

• White Backlight illuminates display for measurements at night or in areas

  with low background light levels.

• Overrange Indication.

• Auto Data Hold when measure released.

• Auto Power Off.

Specification : Range -50oC ~ 600oC (-58oF ~ 1112oF). Response Time < 1 second.

Resolution 0.1o up to 200, 1o over 200o. Basic Accuracy +2% of reading or +2oC / +4oF.

Emissivity Fixed at 0.95. Distance : Spot - 8 : 1. Power Supply : 9V Alkaline Battery.


TN305LC 2 IN 1 INFRARED THERMOMETER with ‘K’ Type  (‘K’ Types Probe is Optional).

 

Range : -60~500oC (-76~932oF). Operating Range : 0~50oC (32~122oF).

Accuracy : +2%, 2oC whichever is greater.

Resolution (-9.9~199.9oC) : 0.1oC / 0.1oF.

Distance to Spot Ratio 8 : 1. Emisivity : 0.1~1 Adjustable.

Measurement Range of Probe : -64~1400oC (-83.2~1999oF).

Accuracy : +1%, 1oC whichever is greater.

Mode : Ave, Dif HiLow Alarm, Max, Min, Lock. Backlite, Buzzer.

Power Supply : LR6 / AA x 2.


TCT103 2 IN 1 INFRARED THERMOMETER with ‘K’ Type

 

Range : -33~220°C (-27~428°F). Operating Range : 0~50°C (32~122°F).

Accuracy : +2%, 2oC whichever is greater. Resolution (-9.9~199.9oC) : 0.1oC / 0.1oF.

Distance : Spot Ratio 1 : 1. Emisivity : 0.1~1 Adjustable.

Measurement Range of Probe : -55~330°C.

Accuracy : +0.8°C,1% whichever is greater.

Mode : Max, Min, Lock. Power Supply : CR2032 x 1.


 368 Pocket Size digital Non-Contact Thermometer

 

Range -22o~120oC (-7o~240oF). Operating Temperaute  0o~40oC (32o~104oF).

Accuracy +2% or reading or +2oC, whichever is greater.

Response Time Less than 0.5sec. Resolution 0.1oF/C.

Emissivity 0.95 fixed.

Distance : Spot Ratio - 1 : 1.3. Battery A003.

 


 TM 910 NARROW SPOT INFRARED THERMOMETER

 

Useful Instrument to measure the surface Temperature of small size and narrow spot target, such as IC, Transistor, Coil, Transformer. LCD 0.5” Display.

Temperature Ranges : -10oC~300oC, 14oF~572oF.

Accuracy : +2% of reading or 2oC (3oF), which ever is greater.

Emissivity : 0.10~0.95. Operating Temperature : 0oC~50oC (32oF~122oF).

Data Output : RS-232 serial PC interface (Cable Optional).

Operating Humidity : < 80% RH. Sampling Time : Approx. 1sec

Power supply : DC 9V Battery. Distance to Spot Ratio - 10 : 1.


 TM-2000 3 in 1 INFRARED THERMOMETER + Pt 100W + Type K/J/R/E/T with Emissivity. Distance to Spot Ratio - 8 : 1

TYPE

RESOLUTION

RANGE

Infrared Thermometer

1oc

-20oC ~ 400oC

PT 100

0.1oC

-200.0oC ~ 850.0oC

Thermocouple ‘K’

0.1oC

-100.0oC ~ 1300.0oC

Thermocouple ‘J’

0.1oC

-100.0oC ~ 1150.0oC

Thermocouple ‘T’

0.1oC

-100.0oC ~ 400.0oC

Thermocouple ‘E’

0.1oC

-100.0oC ~ 900.0oC

Thermocouple ‘R’

1oC

0oC ~ 1700.0oC


GRILLO-H ITALY make HIGH TEMPERATURE INFRA RED THERMOMETER

with Emissivity Setting

 

Range : 600~1400oC / 700~1600oC /1000~1800oC with LASER.

Working Wavelength : 1mm. Focusing Distance : from 800mm to infinite.

Response Time : 5ms. emissivity Range : Adjustable from 0.2 to 1.00.

Target Diameter : 10mm a 800mm. Pointing System : Red LASER class 3A.

Accuracy : 1% +1oC.


 MT-4 MINI TEMP Non-Contact Thermometer

 

*Temperature Range : -18o~260oC. *Accuracy : +2% of Reading.

Preset Emissivity : 0.95. *Distance to Spot Size : 6:1.

*Dimension : 38mm (6 x 4 x 1.5in). *Weight : 227g.


OPTEX JAPAN X-400 THERMO-HUNTER

 

Portable Non-Contact Thermometer for surface Temparature

Measurement Range : 0°C~400°C, Back-light indicator, Measurement Area ψ100/1000mm. Backlight Function enable. “MAX Function to indicate the Maximum Temperature during your Measurement with Emissivity Ratio.


OPTEX JAPAN PT-2LD THERMO-HUNTER

 Measuring Range : -40~510oC (-40~950oF).

Distance to Spot Ratio : 10 : 1.

Accuracy : For Less than 0oC : +3oC, 0~200oC : +2oC.

Repeatability : +1oC (2oF) of reading value.

Emissivity : 0.95/0.7 (Switchable).

Backlight. Temperature Unit : oC / oF.


SMART SENSOR AR-882 INFRARED THERMOMETER.

 

Range : -18 ~ 1500oC (0 ~ 2732oF).

Distance to Spot Ratio : 50 : 1.

Accuracy : 2oC or +2o%.

Repeatability : +1oC (2oF) or 1% of reading value.

Emissivity : 0.95 (Pre-set).

Spectral Response : 8 ~ 14um.

Ambient Operation Range : 0 ~ 40oC (32 ~ 104oF).

Response
Time : 500 mSec 95% Response.

Backlight. Temperature Unit : oC / oF.


INSULATION TESTER CHECKER


ITC 6 Insulation Tester Checker.

 

Checking Ohm ranges of Multimeters.

Checking Low Ohm range on Insulation Testers.

Checking Insulation Mega Ohm ranges on Insulation testers.

Cheking Ohm ranges on Clamp Meters.

Checking range on Milli-Ohm meters.

Checking bench top Multimeters Ohm Range.


INSULATION TESTER ANALOG


1832-IN. ANALOG INSULATION TESTER

 

Battery Operated and designed for very low power  consumption. Visual and Acoustic indication of Warning Voltage. Specification : DC Test Voltage : 1000V, 500V, 250V. Measuring Range  : 1000V, 0-400MW. Output Voltage : Open Circuit @ 1000V, +20% - 0%. Min. Rated Voltage @ 1000V, 1mA. Output Short Circuit Current (Insulation) : + 1.3mA. Accuracy Guaranteed Ranges : 0.05, 10MW 0 - 20MW / 0.2-40MW, +3%. Measuring Range Continuity : 0 - 3W. Measuring Range Resistance : 0 - 500W. Accuracy : 0-3W and 0-500W (%F.S.) : +1.5%. Open Circuit Voltage Output : +5V. Short Circuit Current Output : >210mA. AC Voltage Range : 0-600V. Accuracy : (% of full scale) : +2.5%. Input Impedance : 1.2MW.

 


 

MODEL

3121

3122

3123

3124

 

 

 

DC Test Voltage

2500V

5000V

5000V

10000V

1k~10kV variable

1000V

Measuring Ranges

(automatic change)

2GW / 100GW

(autoranging)

5GW / 200GW

(autoranging)

5GW / 200GW

(autoranging)

10GW / 400GW

(autoranging)

1.6GW / 100GW

(autoranging)

100MW

Primary Effective

Measuring Ranges

Accuracy

0.1 ~ 50GW

0.2 ~ 100GW

0.2 ~ 100GW

0.4 ~ 200GW

0.05 ~ 50GW

1 ~ 100MW

+5% rdg

+10% rdg

Other ranges Accuracy

+10% rdg or 0.5% of scale length

+1% of scale length

Output Voltage and

Set Voltage Indicate

---

DC 0 ~ 10KV

+2%

Withstand Voltage

5000V AC for 1 minute

Power Source

R6P (AA) (1.5V) x 8

Ni-Cd rechargeable battery (1.2V) x 8

Dimensions

200 (L) x 140(W) x 80(D) mm

200 (L) x 140(W) x 80(D) mm


INSULATION TESTER DIGITAL

Model

UR 2060

UR-2061

UR 2070

UR 2071

UR 2072

 

Display Mode

Digital

Rating Voltage

100/250/500/1000

500/1000/2000/2500

500V

1000V

500V / 1000V

Terminal Voltage

Rating Voltage : +5%

Rating Resistance (MW)

0 ~ 2000

Minimum Division

1MW

Accuracy

1 ~ 1000 MW +(5%reg + 3d) / 1001 ~ 1999MW : +(10%reg + 5d)

Short Current (mA)

> 1.5

V AC

---

 

Battery Check

Yes

Insulation Resistance

>50MW (1000V)

Operating Temp. & Humidity

0 ~ +40oC 85%RH

Power Source

6 x 1.5V battery type R6, AA SUM -3


Model

3001B

3111V

Insulation Resistance

Continuity Test

Insulation Resistance

Continuity Test

Test Voltage

500V/1000V

 

250V/500V/1000V

 

Measuring Range

(Mid-scale Value)

200MW (2/20/200MW)

auto ranging

200W(20/200W)

auto ranging

0-100MW(1MW)/

0-200MW(2MW)/

0-400MW(4MW)

50W(20W)

Output Voltage on open circuit

Rated Test Volt. +12%

600mV DC approx.

Rated Test Volt. +10%

0.6V DC approx.

Rated Current

1~1.2mA DC approx.

 

0.8mA DC approx.

 

Output Short Circuit Current

1.5mA DC approx

6mA approx.

2mA DC approx.

300mA approx.

Accuracy Guaranteed Ranges 

 

 

0.05~10MW / 0.1~20MW/

 

Accuracy

+2%rdg +5dgt

+2%rdg +0.1W+1dgt

+5% of indicated value

+3% of scale length

 


KEW-3007 Japan make.

 

Digital Insulation Tester Measuring Range DC Test Voltage 250V / 500V / 1000V. Resistance 0-20W / 0-200MW / 0-2000MW with live circuit warning Buzzer.

 

 DI-6200 DIGITAL INSULATION TESTER.

 

0.7” LCD Battery operated Plastic Body with Automatic Zero Aduj. Measuring Range 200mW / 500V, 1000mW / 1000V sampling time 0.4 second.


SEW-2803 / 2804

SEW-6210 / 6211

SEW-6212IN

Model

2803 - IN

2804 - IN

Test Voltage

(DC V)

0.5KV

1KV

2.5KV    

5KV

1KV

2.5KV

5KV

10KV

Measuring Ranges

0-25GW

0-50GW

0-125GW

0-250GW

0-50GW

0-125GW

0-250GW

0-500GW

Accuracy

0-50GW : +3% of reading/50-250GW : +5% of reading

0-50GW : +3% of reading/50-500GW : +5% of reading

Dimensions

120 (L) x 170(W) x 95(D) mm

Power Source

1.5V (AA) x 8 batteries

Features

• Microprocessor controlled with advanced safety features.

• Displays external voltage warning if present.                   • Auto-ranging / Auto-off.

• Real-time bargraph display of test voltage and voltage decay during discharge.


Model

6210 - IN

6211 - IN

6212 - IN

Test Voltage (DC V)

0.5KV

1KV

2.5KV

5KV

1KV

2.5KV

5KV

10KV

0.5kV to 10kV

(0.5kV increment steps)

Measuring Ranges

(Auto Ranges)

0-25GW

0-50GW

0-125GW

0-250GW

0-50GW

0-125GW

0-250GW

0-500GW

25GW / 0.5kV

25GW at 0.5kV

500GW at 10kV

Accuracy

+ 3% rdg + 1 dgt

Output Current Limit

50uA to 100uA (1W)

Live Warning

> 500V AC

Operating Temp.

0o - 40o C

Humidity

85%

Dimensions

330(L) x 260(W) x 160(D) mm

Power Source

1.5V ‘C’ Alkaline x 8 batteries

Features

• Four insulation test voltages (DC V) (6210-IN & 6211-IN)                                       • Insulation test Voltages

• Bargraph indicates test voltage, decay can be observed during discharge.         (0.5kV - 10kV) (6212-IN)

• Measure insulation test time.                                                                                        • Display warning of external voltage.


INTELLIGENT THERMOMETER


YK-2001TM

YK-200PAM

YK-200PLX

YK-200PIR

YK-200PRH


 YK-2001TM INTELLIGENT Type K/J THERMOMETER

 

Dual function meter’s Super Large 3.½ Digit LCD Display. • Master meter is a professional Type K and Type J Thermometer.

• Microprocessor circuit assures maximum possible accuracy during the measurement.

• Optional expandable plugs satisfy your different measurement demands one time on wide velocity (Anemometer),

light intensity (Light meter), None contact temperature (IR thermometer), and relative humidity (Humidity meter).

Provide you the most convenient way on measuring. • 0.1 degree resolutions for type K and type J thermometer.

• Record maximum and minimum readings. • Data Hold, oC / oF.

Measurement : Type K & J thermocouple. Range : Type K : -100.0~1300.0oC. Type J : -100.0~1150.0oC.

Data Output : RS232 PC Serial Interface.

OPTIONAL TEMPERATURE PROBE & OTHER ACCESSORIES :

YK-200PAM Metal Vane Anemometer Probe : 0.5~40.0m/sm 1.8~144.0km/h, 1.1~89.4mile/h, 1.0~78.1knots, 100~7880ft/min.

YK-200PLX Light Meter Probe : Lux - 2,000 / 20,000 / 50,000 Lux. Feet Candle - 200 / 2,000 / 5,000 FC.

YK-200PIR IR Thermometer Probe : Range -10~300oC / 14~572oF. IR Sensor - Thermocouple Pie. Emissivity Setting - 0.95. Measurement Wave length Region - 6~12 micro meter. Distance Spot Ratio - 7:1.

YK-200PRH Humidity Probe : Humidity Range - 10%~95%RH. Temperature Range - 0~50oC / 32~122oF.

RS-232 : Cable for data transmission.

SW-U801-WIN : Software for Data Logging.