Home LEAK DETECTORS / LEAKAGE
CURRENT TESTERS /
LUX - LUX METER
/ TRANSMITTER & UV LIGHT METER
|
|
|
JL303 Multi
Function Halogen Refrigerant Leakage Detector. • Detects all kinds of halogenated refrigerants. • Single
ColourLED display with 6-Level Leak Alarm. • Real time sensitivity
adjustment. • 14 inches (35.5cm) flexible stainless steel probe. Specification and
parameter : •
Working Mode : Continuous and no limit.
• Reaction time : Instant. • Warm-up : about 6 sec. • Power Supply : 3VDC (2
quality batteries). Application Range : HLD-100 Halogen Leak
Detector can also be used in : • Other systems and storage
/ recovery containers. The unit responds to all halogenated • Detects Halogen Gases in Fire-Extinguishing system. |
|
|
SRD 750A
REFRIGERANT LEAK DETECTOR Summit make. Capable of detection all halogen based gases. High sensitivity combined with an adjustable tick rate wil fallow any service professional to pinpoint tough to find leaks even when the environment is contaminated by other gases. Sensor : Conductivity Polymer Lonization (CPI). Warm Up : Approx. 3 seconds. Response : Instantaneous. Duty Cycle : Continuous. Probe Length : 16”. |
|
|
TIF-5550-A
HALOGEN LEAK DETECTOR
Made in USA. Pump style automatic instantaneous
response to detect leakage of HFC, CFC and HCFC refrigerents. uper sensitive
to trace of Halogen gas to find
leakes in the most contaminated atmospheres, Cordless high efficiancy pump
with detactable probe & ABS carrying case. Optional Accessories : Spare Kit. |
|
|
DL-6054 ACA LEAKAGE TESTER
Features : High
precision AC mA measurement, it isuseful for ACA LEAKAGE measurement. Accuracy : +(1.2%
+ 5d). |
|
|
KEW-2005 3½ Digit AC leakage Tester, Range AC Current 2A (0
~ 1.999A), 20A (0 ~ 19.99A) Accuracy : +2.0%rdg +5dgt (50Hz ~
1kHz).
KEW-2414
3½ Digit AC leakage and Current
Tester, Range Current 100A. ACV 500V, Frequency Selectable Range 50 / 60Hz,
Frequency Response 40Hz-KHz min, Data hold, Sampling Rate 2 sample / sec.,
conductor size 30mm max. |
|
|
KEW-2004 Smallest clamp meter capable of AC
& DC current measurements. Ranges - AC / DC Current : 20 / 200A +1%
rdg +2dgt. ACV : 500V. DCV : 200V. Resistance : 200W. Conductor Size :
f19mm max. Power Source : R6P(AA) (1.5V)x2. |
|
|
FINEST-850
Open Jaw Type Single / Multi Core AC Clamp Meter 3½ digit, 2000 count
LCD display. Continuity check & Diode Test. Data Hold and Auto Power Off. |
|
|||||||
|
Function |
Range |
Resolution |
Accuracy |
Function |
Range |
Resolution |
Accuracy |
|
|
ACA Single-Core Mode 45Hz~1kHz) |
200A |
0.1A |
1.5% +3d |
ACA Multi-Core (45Hz~400Hz) |
100A |
0.1A |
5% +10d |
|
|
ACV (45Hz~400Hz) |
200V |
0.1V |
0.8% 3d |
DCV |
200V |
0.1V |
0.5% +3d |
|
|
600V |
1V |
1.2% +3d |
600V |
1V |
1.0% +3d |
|||
|
W |
2kW |
1W |
1.0% +5d |
Continuity Test |
Open Circuit Voltage
: <3V Threshold : <15W approx |
|||
|
Hz |
2kHz |
1Hz |
1.0% +5d |
Diode Test |
Open Circuit Voltage
: < 3V Max. Test Current :
< 1.0mA |
|||
|
20kHz |
10Hz |
|||||||
|
KEW - 5200 ANALOG LUX METER Low : 0-1000 (Red
Scale), Middle : 0-5,000 (Black Scale), High : 0 -
50,000 Ranges Lux (Black Scale with
10xslide). |
|
BOSSTEK LX-1010B LUX METER Portable Type. Range
0 - 50,000 Lux (3 ranges ). 3.½ Digit LCD Display. Sampling Time : 0.4Sec. Data Hold. |
|
|
TES -1332 DIGITAL LUX METER 3.½ Digit LCD Display,
Measuraing Range 200 / 2,000 / 20,000 / 2,00,000. Sampling Rate 2.5
times per second. Photosensor : Silicon
photodiodes. |
|
LX-101-A DIGITAL LUX METER
3.½ Digit LCD wide
Range Display Portable Type. Range : 0-50,000 LUX (3 range). |
|
|
DIGITAL LX-103 LUX METER
3.½ Digit LCD
Display. Range - LUX : 0~50,000 (3 Ranges). Foot candle : 0~5,000 (3
ranges).z Data hold. |
|
|
LX-107HA LUX METER
3.½ Digit LCD Display.
Range : 0 - 100,000 LUX, (3 Ranges) 0 - 10,000 FC (3 ranges) With data hold
and selection of lighting type (Tungsten, Fluorescent, Sodium or Mercury
Lamp). |
|
|
LX-108 LUX METER
3.½ Digit LCD Display. 3
Ranges : 200 Lux (0 ~ 199.9 Lux) Resolution
0.1 Lux, 2,000 Lux (200 ~ 1,999
Lux) Resolution 1 Lux, 20,000 Lux (2,000 ~
1,9990 Lux) Resolution 10 Lux. Sensor used the
exclusive photo diode and two layers colour correction filter, spectrum meet C.I.E.
photopic. |
|
|
DER EE-3351 LUX METER 3.½ Digit LCD
Display, Measuraing Range 200 / 2,000 / 20,000 / 2,00,000. Accuracy : +(4%rdg+5dgt).
Sensor used the exclusive Photo Diode with Color Correction Filter. |
|
|
LX-1102 LIGHT METER
Large LCD Display 5 Digits
with bar graph indicator. Measurement - 5 Ranges : 40 / 400 / 4,000 / 40,000
/ 4,00,000 Lux. Unit : Lux, Foot-candle. Operating Temp. : 0~50oC (32~122oF). Power Supply : DC 9V Battery. Sensor :
Exclusive photo diode and color correction filter, spectrum meet C.I.E.
Cosine correction factor meet standard Zero Adjustment (40 Lux range only).
Peak / Data Hold. Memory of Max. Min. Recall. Auto Power OFF. RS-232 Data
output. |
|
|
TR-LXT1A4 LUX TRANSMITTER
Measureing Range - Range
1 : 0-2,000 Lux, Range 2 : 2,000~20,000 Lux, Range 3 : 20,000~50,000 Lux.
Output : 4~20mA Range 1 : 0 Lux = 4mA, 1,000 Lux = 12mA, 2,000 Lux = 20mA.
Range 2 : 0 Lux = 4mA, 2,000 Lux = 5.6mA, 2,000 Lux = 20mA. Range 3 : 0 Lux =
4mA, 2,000 Lux = 10.4mA. 50,000 Lux = 20mA. External Adjustment : Zero VR and
Span VR. Powe Supply : 90~260ACV 50~60Hz. Operating Temperature : 0~50oC (32~122oF). Mounting : Din rail or Wall. Body : ABS
Plastic. |
|
|
UV-340 UV LIGHT METER
3.½ Digit LCD Display
13mm (0.5"). Professional, High Quality UV Meter. Ultra-Violet
irradiance measurement of UVA and UVB. Measurement Ranges and Resolution :
1999 uW / cm2 x 1 uW / cm2, 1999 uW / cm2 x 10 uW/cm2. UV Sensor Spectrum : Band pass 290 -390nm. |
|
|
UVA-365 UV LIGHT METER
All same as UV-340
but with Measurement Ranges and Resolution : 199.9 uW / cm2 x 1 uW / cm2, 1.999 mW / cm2 and 19.99 mW / cm2. UV Sensor Spectrum : Point 365mm, Band
pass : 320 -390nm. Accuracy (23+5oC) : +(2% FS + 2dgt) FS : Full Scale. *Calibration is executed
under the UVA light and compare with the standard UVA light meter. |
|
|
UVA-254 UV LIGHT METER
All same as UV-365 but
with shortwave 254nm ultra-violet irradiance measurement. |
|