pH & CONDUCTIVITY METER


 PH-201 HAND HELD DIGITAL PH METER

 

3½ Display. Range : 0~14 PH x 0.01PH with Accuracy of + 0.7 PH (PH5-PH9), + 0.1 (PH 4-PH10) after calibration of 25oC. Calibration knob External PH4 (Slope adjustment).

 

 PE11 Epoxy body ELECTRODE

 

connector : BNC, Size body length - 130mm, Dia. - 10mm, Cable : 1mt.,

for laboratory and field usage.


 PH-206 DIGITAL PH / mV / TEMPERATURE METER

 

3½ Display. Ranges - pH : 0 ~14 x 0.01, mV : 0-1999, Temp. : 0-100oC with Accuracy : +(0.01pH + 1d), mV - +(0.5% + 1d), Temp. : +0.8oC. Calibration Knob : External pH4 (Slope Adj.) and pH7 (Cal. Adj.)

 

 TP-06 ATC TEMPERATURE PROBE

 

Automatical Temperature Control Probe for PH-206.


BOSSTEK P2 PH METER

 

Range : 0~14pH. Resolution : 0.1pH. Accuracy : +0.1pH.


PC-101 Home Swimming Pool Water (PH / Cl2) Tester

 

This meter can test water PH and Cl2. Safety Measure Range for Chlorine : 1.2 ~ 1.7ppm. Safety Measure Range for PH : 7.2 ~ 7.8.


 

 pH600 pH METER

Digital Pocket Size Battery Operated. Measuring Range : 0~14pH. Resolution : 0.1pH. Accuracy : ±0.2 pH.

 


 

 pH 97-WP

Improved model (pH601) Digital Water Proof Pocket Size Battery Operated. Range 0 - 14pH, Resolution 1pH, Accuracy ±0.1 Equipped with Automatic Temp. Compensation feature.

 


 CD-4302 CONDUCTIVITY METER

 

3½ Digit LCD Display, Max. 1999. Measurement Range : 2 Ranges, 1.999mS, 19.99mS.

Resolution : 0.001mS for 1.999mS range / 0.01mS for 19.99mS range. Accuracy : +(1% + 2d) - 23 +5oC, after Calibration. Termperature Compensation : Automatic from 0oC to 50Oc

(32oF to 122oF).


 CD601 WP

Range : 1999µS/cm, Resolution : 1µS/cm, Accuracy : + 2% full Scale, Temp. Compensation : Automatic from 5~50oC, Battery Life : 350 hours of continuous use, Dimension : 150x30x24mm.


 ATC CONDUCTIVITY TESTERS

 

Measuring Electrical conductivity is the best way of checking the amount of salt of dissolved solids (TDS) in water.

Model

Range

Resolution

Accuracy

Temp. Compensation

Battery Life

Dimension

CD600

1990 ppm

10ppm

+ 2%

full

Scale

Automatic

from

5 to 50oC

350 hours of

continuous

use

150

x

30

x

24mm

CD601

1990µS/cm

10µS/cm

CD610

10000 ppm

100 ppm

CD611

19900µS/cm

100µS/cm

CD97

999ppm

1 ppm

+10 ppm


 SMART 3-in-1 Portable Meters SM-801 / SM-802

Model

SM-801

SM-802

Specification

pH

TDS

Conductivity

pH

TDS

Conductivity

Range

0.0~14.0pH

0~1990

ppm

0~1990

mS/cm

0.00~14.00pH

0~4000

ppm

0.00~6.00

mS/cm

Resolution

0.1pH

10ppm

10mS/cm

0.10pH

10ppm

0.01mS/cm

Accuracy

+0.2pH

+2% Full Scale

+0.20pH

+2% Full Scale

Calibraion Solutions

M10007B

M10032B

M10031B

M10007B

M10442B

M10031B

Conversion Factor

0.5

0.68

Calibration

Calibration : Manual 1 Point

Electrode

Electrode : MA850 combination pH / EC / TDS


BUFFER SOLUTION

 

pH : M10007B : pH7.01 / Conductivity : M10031B : 1.413uS/cm. /  M10032B : 1382 ppm TDS buffer solution 25 x 20ml sachets.


pH & CONDUCTIVITY TRANSMITTER


 TR-CDT1AR CONDUCTIVITY TRANSMITTER

 

Measuring Range : (1) 0~200mS, (2) 0.2 ~ 2mS (3) 2 ~ 20mS. Output : (1) 0mS = 4mA, 20mA,
20
mS = 5.6mA, 200mS = 20mA (2) 0mS = 4mA, 0.2mS = 5.6mA, 2mS = 20mA (3) 0mS = 4mA,
2mS = 5.6mA, 20mS = 20mA.
External Adjustment : ZERO VR, SPAN VR.  Power Supply : 90~260 ACV (50/60Hz).

PROBES


CIE-610B LOGIC PROBE

Range : 20MHz Frequency displayble.

 

CIE-625 DIGITAL LOGIC PROBE

Range : 50MHz Frequency Displayable and Logic Pulser.


LP-420D LOGIC PROBE

 

Frequency : 5Hz - 40MHz. Duty : Cycle 0.01% -49.9%. Pulse : Width 9nS-999uS.

Input Signal :  TTL or CMOS level (5V system). Input Impedance : 400KW.  Sample Cycle : 400mS. Display Rate : 2.5 reading / sec.


LP-012X High Impedance Probe made in Japan

 

Frequency Range : DC to 20MHz, Input Resistance : 100 MW, Attenuation : 1/100,

Maximum Input : DC 2000V. *Suited  for measurement of high voltage circuit such as TV horizontal output pulse.


HUNG CHANG HC-OP-27 OSCILLOSCOPE PROBE

Attenuation Ratio 10:1, Band Width 100MHz (at-2dB).


 - CA 113 OS/AT

DC/AC mA Current Probe for Oscilloscope and Automotive Applications.

Specification at 23oC; <70% RH : Effective Measurement Range - For Oscilloscope use : 1mV/10mA - 10mA ~ 2A DC/AC (rms) for 10mV range of the oscilloscope. 2A ~ 20A DC/AC (rms) for 100mA range of the oscilloscope. 1mV/100mA - 100mA ~ 20A DC/AC (rms) for 100V range of the oscilloscope. For Automotive use : 1mV/10mA - 10mA ~ 20A DC/AC (rms) for 200mV range of the multimeter. 1mV/100mA - 100mA ~ 60A DC/AC (rms) for 2V range of the multimeter. System Accuracy : Current Probe accuracy + Oscilloscope / Multimeter accuracy. Current Probe Accuracy : 1mV/10mA : DC Amps 10mA ~ 20A 1.5% +5mA. AC Amps 10mA ~ 10A 2% +5mA (@40Hz ~ 1kHz) / 4% +30mA (@2kHz ~ 10kHz) / 6% +30mA (@10kHz ~ 20kHz). 1mV/100mA : DC Amps100mA ~ 40A 2% +20mA / 40A ~ 60A 4% +0.3A. AC Amps 100mA ~ 40A 2% +30mA (@ 40Hz ~ 1kHz) / 4% +30mA (@1kHz ~ 2kHz) / 6% +30mA (@ 3kHz ~ 5kHz) / 40A ~ 60A 8% +0.3mA (@ 40Hz ~ 5kHz). Input Impedance : 10kW typical.


 HVP-40 HIGH VOLTAGE PROBE

 

Attenuate Ratio : 1:1000. Input Impedance : Approx. 1000MW. Output Impedance : Around 1.1MW. Input impedance of Voltmeter : 10MegaW. Max. Working Voltage : DCV - DC 40 KV.

ACV - Peak AC 40 KV or 28 KV Rms (which values is larger).

Accuracy : DCV - 1 KV~20 KV  + 1%, 20 KV~40KV - + 1.5%. ACV - 1~28 KV rms, 50 / 60Hz –

+ 5%. Temperature Coefficient : < 200 ppm/oC. Cable Length : 1 meter.