P
|
Home pH & CONDUCTIVITY METER / pH & CD TRANSMITTER
/ PROBES – LOGIC PROBE / HIGH VOLTAGE PROBE /
|
PH-201 HAND HELD DIGITAL PH METER
3½
Display. Range : 0~14 PH x 0.01PH with Accuracy of + 0.7 PH (PH5-PH9),
+ 0.1 (PH 4-PH10) after calibration of 25oC. Calibration knob External PH4
(Slope adjustment). PE11 Epoxy body ELECTRODE
connector
: BNC, Size body length - 130mm, Dia. - 10mm, Cable : 1mt., for
laboratory and field usage. |
|
|
PH-206 DIGITAL PH / mV / TEMPERATURE METER
3½
Display. Ranges - pH : 0 ~14 x 0.01, mV : 0-1999, Temp. : 0-100oC with Accuracy : +(0.01pH +
1d), mV - +(0.5% + 1d), Temp. : +0.8oC. Calibration Knob : External pH4
(Slope Adj.) and pH7 (Cal. Adj.) TP-06 ATC TEMPERATURE PROBE
Automatical Temperature Control Probe for
PH-206. |
|
|
BOSSTEK P2 PH METER Range : 0~14pH. Resolution : 0.1pH.
Accuracy : +0.1pH. |
|
|
PC-101 Home Swimming Pool Water (PH / Cl2) Tester This meter can test water
PH and Cl2. Safety Measure Range for Chlorine : 1.2 ~ 1.7ppm. Safety Measure
Range for PH : 7.2 ~ 7.8. |
|
|
pH600 pH METER
Digital Pocket Size Battery Operated. Measuring Range : 0~14pH.
Resolution : 0.1pH. Accuracy : ±0.2 pH. pH 97-WP
Improved
model (pH601) Digital
Water Proof Pocket Size Battery Operated. Range 0 - 14pH, Resolution 1pH,
Accuracy ±0.1 Equipped with Automatic Temp. Compensation feature. |
|
CD-4302 CONDUCTIVITY METER
3½ Digit LCD Display, Max. 1999. Measurement Range : 2 Ranges,
1.999mS, 19.99mS. Resolution : 0.001mS for 1.999mS range / 0.01mS for 19.99mS
range. Accuracy : +(1% + 2d) - 23 +5oC, after Calibration.
Termperature Compensation : Automatic from 0oC to 50Oc (32oF
to 122oF). |
|
|
CD601 WP
Range : 1999µS/cm, Resolution : 1µS/cm, Accuracy : + 2%
full Scale, Temp. Compensation : Automatic from 5~50oC, Battery Life : 350
hours of continuous use, Dimension : 150x30x24mm. |
|
ATC CONDUCTIVITY TESTERS
Measuring Electrical conductivity is the best way of checking the
amount of salt of dissolved solids (TDS) in water. |
|
||||||
|
Model |
Range |
Resolution |
Accuracy |
Temp. Compensation |
Battery Life |
Dimension |
|
|
CD600 |
1990
ppm |
10ppm |
+ 2% full Scale |
Automatic from 5 to 50oC |
350
hours of continuous use |
150 x 30 x 24mm |
|
|
CD601 |
1990µS/cm |
10µS/cm |
|||||
|
CD610 |
10000
ppm |
100 ppm |
|||||
|
CD611 |
19900µS/cm |
100µS/cm |
|||||
|
CD97 |
999ppm |
1 ppm |
+10 ppm |
||||
|
SMART 3-in-1 Portable Meters SM-801 / SM-802
|
|
||||||
|
Model |
SM-801 |
SM-802 |
|||||
|
Specification |
pH |
TDS |
Conductivity |
pH |
TDS |
Conductivity |
|
|
Range |
0.0~14.0pH |
0~1990 ppm |
0~1990 mS/cm |
0.00~14.00pH |
0~4000 ppm |
0.00~6.00 mS/cm |
|
|
Resolution |
0.1pH |
10ppm |
10mS/cm |
0.10pH |
10ppm |
0.01mS/cm |
|
|
Accuracy |
+0.2pH |
+2% Full Scale |
+0.20pH |
+2% Full Scale |
|||
|
Calibraion Solutions |
M10007B |
M10032B |
M10031B |
M10007B |
M10442B |
M10031B |
|
|
Conversion Factor |
0.5 |
0.68 |
|||||
|
Calibration |
Calibration
: Manual 1 Point |
||||||
|
Electrode |
Electrode
: MA850 combination pH / EC / TDS |
||||||
|
BUFFER SOLUTION pH : M10007B : pH7.01 / Conductivity
: M10031B : 1.413uS/cm.
/ M10032B : 1382 ppm TDS buffer solution
25 x 20ml sachets. |
|
TR-CDT1AR CONDUCTIVITY TRANSMITTER
Measuring Range : (1) 0~200mS, (2) 0.2 ~ 2mS (3) 2 ~ 20mS. Output : (1) 0mS = 4mA, 20mA, |
|
|
Range : 20MHz
Frequency displayble. CIE-625 DIGITAL LOGIC PROBE Range : 50MHz Frequency
Displayable and Logic Pulser. |
|
LP-420D LOGIC PROBE Frequency : 5Hz -
40MHz. Duty : Cycle 0.01% -49.9%. Pulse : Width 9nS-999uS. Input Signal :
TTL or CMOS level (5V system). Input Impedance : 400KW. Sample
Cycle : 400mS. Display Rate : 2.5 reading / sec. |
|
- CA 113 OS/AT
DC/AC mA Current Probe for Oscilloscope and
Automotive Applications. Specification at 23oC; <70% RH :
Effective Measurement Range - For Oscilloscope use : 1mV/10mA - 10mA ~ 2A
DC/AC (rms) for 10mV range of the oscilloscope. 2A ~ 20A DC/AC (rms) for
100mA range of the oscilloscope. 1mV/100mA - 100mA ~ 20A DC/AC (rms) for 100V
range of the oscilloscope. For Automotive use : 1mV/10mA - 10mA ~ 20A DC/AC
(rms) for 200mV range of the multimeter. 1mV/100mA - 100mA ~ 60A DC/AC (rms)
for 2V range of the multimeter. System Accuracy : Current Probe accuracy +
Oscilloscope / Multimeter accuracy. Current Probe Accuracy : 1mV/10mA : DC
Amps 10mA ~ 20A 1.5% +5mA. AC Amps 10mA ~ 10A 2% +5mA (@40Hz ~
1kHz) / 4% +30mA (@2kHz ~ 10kHz) / 6% +30mA (@10kHz ~ 20kHz).
1mV/100mA : DC Amps100mA ~ 40A 2% +20mA / 40A ~ 60A 4% +0.3A.
AC Amps 100mA ~ 40A 2% +30mA (@ 40Hz ~ 1kHz) / 4% +30mA (@1kHz
~ 2kHz) / 6% +30mA (@ 3kHz ~ 5kHz) / 40A ~ 60A 8% +0.3mA (@
40Hz ~ 5kHz). Input Impedance : 10kW typical. |
|